Skip to content
Enerlensby SeamCreate account

Methodology and data sources

Every calculation, in the open.

This page is generated from the same code that runs the platform, so it cannot drift from what you see. Values marked Provisional are still being reviewed and are shown as such throughout the product.

What it is: a screening tool that estimates likely savings, costs and carbon, so you can decide where to look harder.

How sure we are: every figure carries a confidence level, and benefits are shown as ranges, never single numbers.

What it does not do: it is not a design, a survey, a quotation or a guarantee.

Principles

  • Every number shows its source, date and confidence.
  • Every score and recommendation is explainable, deterministic and auditable. The components and weights are always visible. There are no black-box AI decisions.
  • Uncertainty is shown, never hidden. Benefits are ranges.
  • One calculation engine is used by the browser, server, reports and alerts. There is no second copy that could disagree.

Confidence and freshness

Each record has a data confidence level based on where it came from, a last-updated date, and a freshness rating against how often that source normally updates.

Very highMetered half-hourly data▮▮▮▮▮
HighDisplay Energy Certificate▮▮▮▮▮
MediumRecent EPC (5 years or less)▮▮▮▮▮
LowOlder EPC (5 to 10 years)▮▮▮▮▮
Very lowFully modelled assumptions▮▮▮▮▮

Site confidence is a 0 to 100 score from five visible components:

Site confidence weights

Data Level30%
Freshness25%
Meter Coverage20%
Completeness15%
Evidence Quality10%

Scores and weights

Opportunity is technical potential. Readiness is deliverability. Priority blends them and then discounts for thin data. Defaults are below, and every weight can be changed at account level in Settings.

Opportunity

Savings30%
Carbon25%
Solar20%
Heat15%
Funding10%

Readiness

Ownership18%
Occupier10%
Half Hourly12%
Planning12%
Grid14%
Funding Eligibility10%
Evidence12%
Stakeholders12%

Priority

Priority = (Opportunity × 50% + Readiness × 50%) × confidence multiplier. The multiplier runs from 0.85 at zero confidence up to 1.00 at full confidence.

Why a multiplier and not a third added term? Adding confidence as a score would reward sites we know little about only when they happen to look good, and could lift a poorly evidenced site above a well evidenced one. A multiplier can only hold a site back, never push it up. The range shown beside each Priority score widens as confidence falls.

Measures and ordering

Measures are applied in a fixed order, each acting on the energy that remains after the one before, so benefits are never double counted:

  1. Baseload reduction
  2. Fabric and controls
  3. Heat pump
  4. Solar PV
  5. Tariff optimisation

Solar is therefore sized on demand after baseload savings and after a heat pump has added electrical load. All benefits are shown as low, central and high ranges, including across lifetime energy price scenarios.

Heat pump results are shown honestly: where running costs rise at current prices, we say so and flag it. Flags also cover radiators, building age and supply capacity.

Default assumptions

These are the defaults used until you override them. An override always wins; if the underlying default later changes significantly you are alerted to review it.

AssumptionValueSourceUpdatedConfidence
Electricity unit price (non-domestic)22 / 27 / 33 p/kWhProvisional1 Nov 2026Low
Gas unit price (non-domestic)5.5 / 7 / 9 p/kWhProvisional1 Nov 2026Low
Export rate4 / 8 / 15 p/kWhProvisional1 Nov 2026Low
Solar specific yield (Pennine, south-facing)780 / 860 / 930 kWh/kWp/yrBeing reviewed1 Nov 2026Low
Commercial solar installed cost850 / 1100 / 1400 £/kWpProvisional1 Nov 2026Low
Roof area per kWp5.8 m²/kWpTypical modern module layout, pitched roof1 Nov 2026Medium
Solar running cost1 % of capex / yrProvisional1 Nov 2026Low
Heat pump seasonal COP2.4 / 3 / 3.6 SCOPTypical range for retrofit air-source units1 Nov 2026Medium
Heat pump installed cost700 / 950 / 1300 £/kW thermalProvisional1 Nov 2026Low
Existing boiler seasonal efficiency0.82 fractionTypical for non-condensing and older condensing plant1 Nov 2026Medium
Discount rate (real)0.035 fractionHM Treasury Green Book social rate (3.5%)1 Nov 2026Medium
Analysis period25 yearsTypical solar asset life1 Nov 2026Medium
Solar output degradation0.5 % / yrTypical module warranty assumption1 Nov 2026Medium

The Energy Cost Outlook is three scenarios (low, central, high) for electricity and gas over 1 to 10 years, from public sources only. They are scenarios, not predictions. Current growth rates are provisional and reviewed each quarter.

Verification

For operational projects with half-hourly data we compare predicted and measured savings using a recognised approach (IPMVP, Option C: whole building). A baseline is fitted to the period before installation and adjusted for weather (heating degree days) and occupancy (occupied days). The method, baseline period and adjustments are shown on every result.

Fit quality is reported as R², CV(RMSE) and NMBE, and savings carry an uncertainty range at about 80% confidence, following the ASHRAE Guideline 14 approach. Benefit status moves from Estimated to Verified only after this process. Enerlens is built to verify outcomes; verified case studies follow once projects have run for 12 months.

Carbon

Carbon uses government greenhouse gas conversion factors, aligned with the GHG Protocol (Scope 1 for gas, Scope 2 location-based for electricity) and suitable for public sector and SECR-style reporting. Factors update annually.

Electricity

0.207 kg CO₂e / kWh

Government GHG conversion factors, UK electricity (generation), 2024

Being reviewed

Gas

0.183 kg CO₂e / kWh

Government GHG conversion factors, natural gas (gross CV), 2024

Being reviewed

Data sources and licences

Boundaries (ONS), roofs and footprints (Environment Agency LIDAR and open footprints), solar potential (our own model with PVGIS), actual energy use (Display Energy Certificates), modelled energy (non-domestic EPCs), grid capacity (DNO heatmaps), planning constraints, and energy prices and carbon factors (government and regulator publications). Open data is used under its published licence and attributed here.

Company ownership and title boundaries use Land Registry data; the licence for use inside a paid product is under review. Google Solar data is shown live and on demand in paid tiers only, on a Google map, and is not stored. Funding information is curated by Seam and shows a last verified date. See the Data page for live freshness by layer.

What this is not

  • Screening only. It is not a design, a quotation or a guarantee of performance.
  • Funding eligibility is indicative. The funding fit assessment is Enerlens’s own, not the funder’s.
  • Energy prices are scenarios, not predictions. Nothing here is financial advice.
  • Enerlens does not provide consultancy, install technology, broker projects or recommend suppliers.